The report says one model, the label says another. Whether that is a five-day clerical fix or a full retest depends on which of the two is actually wrong.
The report arrives, the buyer's compliance team reads it, and the email comes back short: this is not our model. The report says TC-30W. The carton, the rating label and the purchase order all say TC-30B. The product has not changed by a single component, but the document that is supposed to prove it was tested now describes something the buyer cannot trace.
This is one of the most common document problems we see after testing, and it is almost never a testing failure. It is an identity failure. The question that decides everything that follows is not "can the report be fixed" but a narrower one: was the model number wrong on the paper, or was it wrong on the sample?
Split the problem in two before you contact anyone.
Everything else in this article is detail hanging off that distinction. Get it wrong in either direction and you either pay for a retest you did not need, or you ship with a document set that falls apart the first time a customs officer or a marketplace compliance team looks closely.
A test report is not a standalone document. It is one link in a chain, and every other link in that chain has to name the same product. When one link disagrees, the whole chain is questioned - not just the report.
| Document | What it states | What a mismatch causes |
|---|---|---|
| Test report | Description and identification of the item tested, as required by the laboratory's reporting rules | Buyer rejects the file; the document no longer describes anything you can ship |
| Declaration of conformity | Identification of the apparatus that allows traceability - typically model, type or batch reference | The DoC names a model with no supporting report, so the presumption of conformity has nothing behind it |
| Rating label and packaging | The model the customer physically receives | Label and report describe different products; the label is the first thing a market surveillance officer reads |
| Technical file | The complete evidence set, kept for the retention period | An auditor comparing documents finds an unexplained gap and asks for the missing test |
| Commercial documents | Model on the PO, invoice and packing list | Customs or the buyer's goods-in reject the consignment as not matching the declared certification |
| Marketplace listing | Model field in the seller's compliance portal | Listing suspension during a documentation check, often with the stock already in the fulfilment centre |
In the EU, the declaration of conformity has to identify the product in a way that allows traceability, and the technical file has to contain the test reports that support it. A report for TC-30W sitting behind a DoC for TC-30B is not a small filing error. It means the file, as assembled, does not demonstrate conformity for the product being placed on the market. That is the sentence a buyer's compliance manager will use when they reject the shipment, and they are technically correct when they say it.
The fix depends entirely on the cause, so identify the cause before drafting an email.
| Situation | Whose mistake | Correction path | Evidence the laboratory will want |
|---|---|---|---|
| Transcription error at the laboratory | Laboratory | Administrative amendment, no retest | Photo of the sample label, the original application form, the report page in question |
| Wrong model typed on your own application form | Applicant | Administrative amendment, sometimes with a fee | Written request from the applicant, corrected application, label photo |
| Factory internal model on the report, brand model on the label (ODM) | Neither, usually - two naming systems | Amendment to add the brand model, or a model equivalence statement in the file | Relationship between the two names, brand authorisation, label artwork for both |
| Family report lists only the representative model | Scope decision made at quotation stage | Amendment with a model list, only if the variants were declared and covered | The original family declaration, worst-case justification |
| Model renamed after the report was issued | Commercial decision | Not a correction - see the next section | Nothing; this is a change of identification, not a typo |
The third row deserves a note because it is the one that produces the most arguments. A factory that has sold the same board for years under an internal code will put that code on everything, including the samples it sends to the laboratory. The brand owner then prints a different name on the retail box. Both parties believe they are right. The report is accurate about the item tested; the label is accurate about the item sold. What is missing is a document that ties the two names together, and that document is what the buyer actually needs - sometimes written as a model equivalence statement, sometimes handled by adding the brand model to the existing report.
If the model number is wrong and the hardware moved at the same time - a different adapter, a new PCB revision, an added radio mode, a firmware change that alters output power - stop treating this as a paperwork problem. A corrected report would then describe a product that was never tested, which is worse than the original error, because it looks clean.
The same applies when the model on the report is a placeholder that was never the real product name, or when the tested sample was a hand-built prototype with no label at all. In those cases the honest route is a new test or a documented delta evaluation against the closest tested configuration. We have written separately about what counts as a component change that requires retesting, and the reasoning there applies directly: it is the configuration that was tested, not the name it carries.
This surprises people who assume any accredited laboratory can "correct" a document. It cannot. A report is the issuing laboratory's statement about work it performed. A second laboratory has no access to the raw data, the sample photos or the measurement traceability behind it, so it can only test again and issue its own report - it cannot amend someone else's.
Accredited laboratories operate under rules that make this explicit. In ISO/IEC 17025:2017, clause 7.8.8 (adopted in China as CNAS-CL01:2018 clause 7.8.8), any change to an issued report has to be clearly identified, and where appropriate the reason for the change has to be stated. An amendment is issued as a further document carrying the wording "Amendment to Report, serial number..." or an equivalent statement. If instead a complete new report is issued, it must be uniquely identified and must reference the original it replaces. The clause exists so that two versions of "the same" report cannot circulate without anyone noticing which one is current.
Two practical consequences follow. First, expect the amendment to be a separate numbered document - for example an amendment to report number XXXX-1 - rather than the original PDF quietly reissued with a corrected line. That is normal and buyers accept it. Second, the applicant named on the report controls the request. If the applicant is your factory or your supplier, the laboratory may decline to act on your instruction without written authorisation from the applicant, even though you own the brand.
The accreditation mark matters here too. A report carrying a CNAS or ILAC-MRA mark is amended under the accreditation body's rules, and the amendment carries the same mark. A report without an accreditation mark can also be amended, but it starts from a weaker position when a buyer or an authority questions it.
Most delays in this process come from incomplete requests, not from laboratory reluctance. A request that arrives with everything attached is usually handled in one pass.
A short written request is enough. It does not need to be a legal letter, but it does need to state the error, the correct value, the evidence, and the destination. If the error is yours, say so - laboratories are considerably more cooperative with applicants who do not open by blaming the typist.
The amendment is not the end of the job. Once the report changes, everything downstream has to change with it, or you have simply moved the inconsistency.
We advise against a correction in four situations, and in each of them the client initially wanted one.
For a genuine transcription error, no bench time is involved, so the work is administrative review and re-issue. In our experience that is typically a few working days, and many laboratories charge nothing or a nominal administrative fee - but confirm before you promise a date to a customer. Timelines stretch when the report has already been uploaded to an accreditation or certification system, when the original technical reviewer is unavailable, or when the request comes from someone who is not the applicant.
For anything that touches technical content, the clock resets to testing. There is no version of this where a laboratory legitimately re-dates a report to cover a configuration it did not measure, and any offer to do so should be treated as a warning sign about that laboratory rather than a shortcut.
A wrong model number is not a cosmetic defect in a document; it breaks the identification chain that connects the tested sample, the declaration, the label and the shipment. Whether it can be corrected in a few days depends on one question that has nothing to do with paperwork: did the laboratory test the product you are now selling? If it did, an amendment restores the chain and costs almost nothing. If it did not, no correction will, and the sooner that is accepted the less expensive the year becomes.
We review report sets against labels, declarations and technical files before they go to a buyer, and where we performed the EMC, RF and safety testing we issue the amendment ourselves - including when the error originated on the sample label rather than in our typing. Send the report page, the label photo and the market you are shipping to, and we will tell you which of the two situations you are in.
Send the report page with the model number, a photo of the rating label and the market you are shipping to. We will tell you whether this is an administrative amendment or a case where the product itself needs to be tested again - and if we issued the report, we will handle the amendment.
No. A report is the issuing laboratory's own statement about work it performed, so only that laboratory can amend it. Another laboratory would have to test the product again and issue its own report, which is a new test, not a correction.
A letter from the factory is not an amendment. Some buyers accept a clarification letter in the short term, but market surveillance and most compliance teams want the corrected document from the laboratory that issued the original, with a statement that it replaces the earlier version.
Only if the technical content changes. If the sample, configuration and results stay the same and only an identification detail was entered incorrectly, the amendment is administrative. If the model is changing because the hardware changed, that is a new test or a delta evaluation, not an amendment.
It depends whether that suffix was declared and evaluated when the family was scoped. If the variant was listed in the application and covered by the worst-case justification, an amendment can usually add it to the report. If it was never declared, the report does not cover it, and a new evaluation is needed.
Only if the report is the accurate record and the label was wrong. Relabelling a product to match a report for a different configuration inverts the evidence and creates a worse problem than the one being solved. Decide which document is wrong first, then correct that one.
Keep it in the technical file with a note that it was replaced and why, and take it out of circulation with buyers and distributors. For EU files the documentation has to be kept for ten years after the product is placed on the market, and that applies to the history of the file, not only its final state.