EMC, safety, battery, chemical and environmental testing under one roof - the test work behind every certificate we help you obtain.
Emissions and immunity testing for electronic and electrical products. Required for FCC, CE/EMC, UKCA, RCM, VCCI and KC approvals. Request this test →
Anechoic chamber measurements from 30 MHz upward to CISPR 32 / EN 55032 and FCC Part 15 limits, including the peak and average scans used in FCC and CE reports.
Disturbance voltage on mains and signal ports from 150 kHz to 30 MHz (CISPR 32 / CISPR 11).
Field immunity testing from 80 MHz to 6 GHz per IEC 61000-4-3.
Contact and air discharge testing per IEC 61000-4-2, up to 8 kV contact / 15 kV air.
Fast transients (IEC 61000-4-4) and surge immunity (IEC 61000-4-5) on AC and signal lines.
Immunity to conducted disturbances induced by RF fields per IEC 61000-4-6.
IEC 61000-4-11 testing for AC power port immunity.
EN 61000-3-2 harmonic current and EN 61000-3-3 voltage fluctuation / flicker testing.
Transmitter and receiver testing for Bluetooth, Wi-Fi, cellular and short-range radio products - the RF work behind FCC, ISED, RED, TELEC/MIC, SRRC, KC and NBTC approvals. Request this test →
Conducted and radiated output power, power spectral density, occupied bandwidth, band-edge compliance and unwanted emissions for radio transmitters (FCC Part 15, ETSI EN 300 328 / EN 301 893 / EN 300 220 and similar standards).
Out-of-band and spurious domain emissions, conducted and radiated, measured against the limits of the applicable radio standard and market regime.
Frequency tolerance, frequency-hopping behaviour and adaptive mechanisms, including the adaptive frequency hopping checks in EN 300 328.
Receiver blocking, adjacent-channel selectivity and receiver spurious emissions under the RED receiver requirements that apply to current EN radio standards.
Mobile and fixed RF exposure evaluations per FCC 47 CFR 1.1310 / 2.1093 and EN 62311 / EN 50566, with SAR referral where separation distances are short.
Support for host products integrating certified Bluetooth, Wi-Fi, Zigbee or LoRa modules, including modular approval documentation review.
Specific Absorption Rate measurement for phones, tablets, wearables and any radio product used close to the body, per the SAR clauses of FCC, CE and other regimes. Request this test →
SAR measurements per IEC/IEEE 62209-1 and EN 50566 for devices used against the head and worn or held against the body.
Extremity SAR per IEC/IEEE 62209-2 for smart watches, armbands and other limb-worn radio devices.
SAR evaluation per FCC 47 CFR 2.1093 and the applicable KDB procedures, including the test configurations US grants are based on.
SAR assessment for products with multiple active radios (cellular, Wi-Fi, Bluetooth), including composite ratio and separation-distance analysis.
Precision robotic scanning with tissue-simulating phantoms and dosimetric probes at the frequencies required by the applicable standards.
Evaluation of proximity-sensing power reduction where permitted by the applicable regulatory procedure.
Electrical safety testing to the IEC/EN/UL standards behind CE, UKCA, CB, GS and North American certification. Request this test →
Safety of audio/video, information and communication technology equipment - the current standard replacing IEC 60950-1 and IEC 60065.
Household and similar appliance safety, part 1 with the relevant part 2 (-2-x) sections.
Luminaires and lighting equipment safety.
Battery pack and power bank safety standards.
Temperature rise, dielectric strength, leakage current and earth continuity.
Mechanical strength, stability, enclosure tests and critical component assessment.
Life, durability and accelerated testing that proves a product keeps working over its claimed service life - the evidence behind warranty and quality claims. Request this test →
Elevated temperature, humidity and combined-stress ageing to estimate service life within a practical test window.
Charge/discharge cycles, switch, button, connector plug-unplug and actuation endurance to specification limits.
Repeated drop, tumble, torsion and flex testing for handheld and portable products.
Reliability prediction based on recognised models (e.g. Telcordia SR-332, MIL-HDBK-217) supporting warranty and tender documents.
Sequential temperature, humidity and vibration profiles that expose weaknesses single-stress tests miss.
Highly accelerated step-stress screening to find design and workmanship margins before mass production.
Screening and verification of restricted substances for EU, US and brand-owner requirements. Request this test →
XRF screening with wet-chemistry confirmation for the ten restricted substances in Directive 2011/65/EU.
Screening for substances of very high concern against the current ECHA candidate list.
Lead, cadmium, phthalates and other listed chemicals to support warning-label decisions.
Polycyclic aromatic hydrocarbons testing to AfPS GS 2019:01 PAK for skin-contact materials.
DEHP, DBP, BBP and DIBP testing for plastics and coated parts (relevant to RoHS, REACH and CPSIA).
EN 71-3 migration testing and related toy chemical requirements.
Halogen-free verification and screening for PFAS in response to brand-owner and emerging EU requirements.
Heavy metals in packaging per CONEG/TPCH model legislation.
Safety, performance and transport testing for lithium-ion and lithium polymer cells, battery packs and battery-powered products. Request this test →
Transport testing per the UN Manual of Tests and Criteria - altitude, thermal, vibration, shock, external short circuit, impact/crush, overcharge and forced discharge.
Safety requirements for portable sealed secondary cells and batteries - the standard behind BIS, KC and many CB-scheme approvals.
Chinese national standard for lithium cells and packs in portable electronics - the technical basis of the portable power bank CCC requirement.
Overcharge, over-discharge, external short circuit and forced discharge at cell and pack level.
Crush, impact, drop, vibration and shock testing.
Temperature cycling, thermal abuse and low-pressure (altitude) testing.
Capacity verification, cycle life and internal resistance measurement.
Preparation and review of material safety data sheets required by carriers and platforms.
Efficiency measurement and registration support for the world's major energy programmes. Request this test →
EU standby and off-mode power, efficiency requirements and EU energy label measurement.
External power supply and appliance efficiency testing to US Department of Energy test procedures.
California Energy Commission Title 20 measurement and database listing support.
Testing to Energy Star and DesignLights Consortium specifications.
Korean MEPS and Japanese Top Runner efficiency measurement for regulated products.
Australian GEMS efficiency registration testing.
Efficiency measurement for computer and server power supplies across the load grid.
No-load and standby power consumption measurement for adapters and chargers.
Climatic and mechanical environment testing per the IEC 60068 series, plus ingress protection ratings. Request this test →
Cold, dry heat, damp heat cyclic and steady-state testing (IEC 60068-2-1/-2/-30/-78).
Rapid temperature change testing (IEC 60068-2-14).
Sinusoidal vibration, bump and mechanical shock testing (IEC 60068-2-6/-27/-64).
Free-fall drop testing for products and packaging.
Neutral salt spray and cyclic corrosion testing (IEC 60068-2-11/-52).
Ingress protection testing and verification per IEC 60529 - dust and water jets, immersion claims.
Testing for high-altitude use and air transport conditions (IEC 60068-2-13).
Material and enclosure flammability testing that feeds directly into safety files (IEC 62368-1, IEC 60335-1) and the GS mark. Request this test →
Glow-wire flammability, ignition and end-product testing per IEC 60695-2-11/-2-12/-2-13 (IEC 60335-1 clause 30).
Needle-flame test per IEC 60695-11-5 for small parts and materials.
Horizontal and vertical burning of plastic materials - HB, V-0, V-1, V-2, 5VA/5VB (IEC 60695-11-10/-11-20).
Comparative tracking index (CTI) of insulating materials per IEC 60112.
Overload and limited short-circuit scenarios feeding the flammability assessment in end-product standards.
Verification that a product does what its specification claims - before your customers or the marketplace find out otherwise. Request this test →
Performance measurement against the claimed specification sheet.
Cycle, ageing and accelerated-life testing to estimate service life.
Capacity, efficiency and runtime claims checked against marketing figures.
USB PD, Quick Charge and Qi charging behaviour across reference devices.
IP claim verification (e.g. IPX4, IPX7) before the claim goes on the box.
Incoming and in-process inspection programmes and factory acceptance testing.
High-power AC/DC sources and electronic loads for temperature rise, overload, short-circuit and efficiency testing of larger electrical equipment. Request this test →
Thermal measurement of equipment running at rated power until stabilisation.
Overload, limited short-circuit and abnormal operation testing per the applicable product standard.
Withstand voltage testing at the voltages required for higher-power equipment.
Performance, efficiency and protection-function testing for inverters, UPS systems and energy storage equipment.
High-current output performance, efficiency curves and protection verification.
Harmonic current and flicker measurement for higher-power equipment connected to the mains.
Inspection methods that check internal construction and materials without damaging the sample - widely used for incoming inspection, failure analysis and RoHS screening. Request this test →
Internal inspection of solder joints, BGA voids, connectors and assemblies without opening the product.
Rapid on-site elemental screening for RoHS and alloy identification.
3D CT imaging for internal structure and defect localisation.
Ultrasonic examination of materials, welds and bonding quality.